Fronius Symo 10.0-3-M |
Max. input current (Idc max1 / Idc max2) |
27.0 A / 16.5 A1) |
Max. usable input current total (Idc max1 + Idc max2) |
43.5 A |
Max.array short circuit current (MPP1 / MPP2) |
40.5 A / 24.8 A |
Min. input voltage (Udc min) |
200 V |
Feed-in start voltage (Udc start) |
200 V |
Nominal input voltage (Udc,r) |
600 V |
Max. input voltage (Udc max) |
1,000 V |
MPP voltage range (Umpp min - Umpp max) |
270 - 800 V |
Number of MPP trackers |
2 |
Number of DC connections |
3 + 3 |
Max. PV generator output (Pdc max) |
15.0 kWpeak |
OUTPUT DATA |
|
AC nominal output (Pac,r) |
10,000 W |
Max. output power |
10,000 VA |
AC output current (Iac nom) |
14.4 A |
Grid connection (voltage range) |
3~NPE 400 V / 230 V or 3~NPE 380 V / 220 V (+20 % / -30 %) |
Frequency (frequency range) |
50 Hz / 60 Hz (45 - 65 Hz) |
Frequency range (fmin - fmax) |
45 - 65 Hz |
Total harmonic distortion |
1.8 % |
Power factor (cos φac,r) |
0 - 1 ind. / cap. |
GENERAL DATA |
|
Dimensions (height x width x depth) |
725 x 510 x 225 mm |
Weight |
34.8 kg |
Degree of protection |
IP 66 |
Protection class |
1 |
Overvoltage category (DC / AC)2) |
1 + 2 / 3 |
Night time consumption |
< 1 W |
Inverter design |
Transformerless |
Cooling |
Regulated air cooling |
Installation |
Indoor and outdoor installation |
Ambient temperature range |
-25°C to +60°C |
Permitted humidity |
0 % to 100 % |
Max. altitude |
2,000 m / 3,400 m (unrestricted / restricted voltage range) |
DC connection technology |
6x DC+ and 6x DC- screw terminals 2.5 mm² - 16 mm² |
AC connection technology |
5-pin AC screw terminals 2.5 mm² - 16 mm² |
Certificates and compliance with standards |
ÖVE / ÖNORM E 8001-4-712, DIN V VDE 0126-1-1/A1, VDE AR N 4105, IEC 62109-1/-2, IEC 62116, IEC 61727, AS 3100, AS 4777-2, AS 4777-3, CER 06-190, G83/2, UNE 206007-1, SI 4777, CEI 0-16, CEI 0-21, NRS 097 |
EFFICIENCY |
|
Max. efficiency |
98.0 % |
European efficiency (ηEU) |
97.4 % |
η at 5 % Pac,r3) |
87.9 / 92.5 / 89.2 % |
η at 10 % Pac,r3) |
91.2 / 94.9 / 92.8 % |
η at 20 % Pac,r3) |
94.6 / 97.1 / 96.1 % |
η at 25 % Pac,r3) |
95.4 / 97.3 / 96.6 % |
η at 30 % Pac,r3) |
95.6 / 97.5 / 96.9 % |
η at 50 % Pac,r3) |
96.3 / 97.9 / 97.4 % |
η at 75 % Pac,r3) |
96.5 / 98.0 / 97.6 % |
η at 100 % Pac,r3) |
96.5 / 98.0 / 97.6 % |
MPP adaption efficiency |
> 99.9 % |
PROTECTIVE DEVICES |
|
DC insulation measurement |
Yes |
Overload behaviour |
Operating point shift, power limitation |
DC disconnector |
Yes |
Reverse polarity protection |
Yes |
INTERFACES |
|
WLAN / Ethernet LAN |
Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON) |
6 inputs and 4 digital in/out |
Interface to ripple control receiver |
USB (type A socket)4) |
Datalogging, inverter update via USB flash drive |
2 x RS422 (RJ45 socket)4) |
Fronius Solar Net, Interface protocol |
Signalling output4) |
Energy management (floating relay output) |
Datalogger and Webserver |
Included |
External input 4) |
S0 meter connection / Evaluation of overvoltage protection |
RS485 |
Modbus RTU SunSpec or meter connection |